Saeco TALEA GIRO Service Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
6.1 Reset coffee grounds drawer.
The “empty coffee grounds drawer” message is signalled by a “coffee” beverages counter
controlled by the appliance electronics.
The counter is cleared “empty coffee grounds drawer” reset message:
1. After 13 coffees, if the grounds drawer is removed for more than 5 seconds.
2. Each time the grounds drawer is removed for more than 5 seconds when an “empty
coffee grounds drawer” alarm has been generated (it is assumed that the grounds
drawer has been emptied).
N.B:
If the 12th coffee is actually a “double coffee”, the “empty coffee grounds drawer” alarm will be
generated at the 14th coffee. As a result, the counter for the “empty coffee grounds drawer” in
this case would be reset at the 14th coffee.
6.2 Water reserve
Talea models have a fixed reserve (turbine pulses) to ensure the selected beverage can be fully
(partially or totally) dispensed each time the capacitive sensor registers the presence of water
in the water tank. Otherwise, the appliance displays the “fill water tank” message and will not
dispense the beverage.
The beverage will be dispensed in full or in part depending on whether the remaining reserve is
enough to cover the programmed length of the selected beverage.
On selection, a message requests that the water tank is filled.
Example:
e.g: sensor registers presence of water (+10cc).
Hypothesis 1) A 60cc beverage is selected, 50cc is taken from the reserve, the beverage is
dispensed in full, and the “fill water tank” message appears.
Hypothesis 2) A 110cc beverage is selected, 90cc is taken from the reserve, the product is
dispensed in part (100cc), and the “fill water tank” message appears.
Hypothesis 3) A double 110cc coffee is selected; the first is dispensed in part (100cc),
the fill tank message appears, then the second one is dispensed in full (110cc).
Hypothesis 4) Double 40cc coffees are selected; the appliance dispenses both in full.
10 cc
Starting water level
Capacitive sensor
actual 90 cc level
not configurable
via SW
1/6
TALEA Section 06
REV00 - August 06
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 59 60

Comments to this Manuals

No comments