5.3 Error messages for service personnel
16/17
PRIMEA Section 05
REV00 - August 06
Code
Applicable models:
Primea-Odea-Talea
Brief description Description
01 All models Coffee grinder 1 blocked.
The coffee grinder is blocked (grinders blocked or sensor not reading
properly).
02 Primea Coffee grinder 2 blocked.
The coffee grinder is blocked (grinders blocked or sensor not reading
properly).
03 All models Brew group blocked in work position.
Microswitch not released in up position after 3”, torque error trying to
move down, descent time out exceeded.
04 All models Brew group blocked in home position.
Microswitch not released in down position after 3”, torque error trying to
move up, ascent time out exceeded.
05 All models Water circuit blocked. No water in turbine.
06 Primea Multivalve error. Multivalve blocked.
08 Primea Cappuccinatore valve blocked. The cappuccinatore has failed to reset because it can’t excite microswitch.
09 Primea
Communication error between CPU and
POWER.
Communication interrupted for more than 2 seconds.
10-11 All models Various sensor errors. Water heater sensors shorted or in open circuit.
12-13 Primea Various sensor errors. Steam heater sensors shorted or in open circuit.
14-15 All models Various temperature errors. Heater temperatures out of control.
16 All models Both microswitches activated on brew group. The work and home microswitches have both been activated.
17 All models Memory error. Impossible to read or write to e2prom.
18 All models Clock error. Memory defect or impossible to set.
19 All models No zero crossing. No zero crossing on card, could be caused by power card.
20 All models Cup lift error.
The two stroke end position microswitches are activated at the same
time.
On models in the new Primea, Talea and Odea ranges, errors recorded can be viewed on the display (during diagnosis) or on a PC (with programmer). The fol
-
lowing are saved:
A) The last 20 errors to be recorded.
B) Total number of errors (not all models).
Since production (total).
Since last service (partial).
Current.